How to Use a Laser Distance Meter (C6 & R7 Models)
The C6 and R7 Laser Distance Meters from Temu are powerful tools for quick and precise measurements. This guide explains how to operate the device, use advanced functions, and troubleshoot issues effectively.
🔌 Getting Started: Powering On and Off
- Turn On: Press the
STARTbutton to activate the device. The backlight will turn on and enter single measurement mode. - Turn Off: Hold the power button. If idle, the device will shut down automatically after 3 minutes.
📏 Basic Measurement Functions
1. Single Distance Measurement
- Press
STARTto turn on the laser. - Aim at the target and press
STARTagain to take a reading. - Measurement displays instantly.
2. Continuous (Max/Min) Measurement
- Long press
STARTto activate continuous mode. - Display shows:
– Top: Minimum distance
– Middle: Maximum distance
– Bottom: Current reading - Press the power button to exit or wait 5 minutes for auto-exit.
3. Addition & Subtraction
- Press
+/-to toggle between add/subtract modes. - Addition: Current + next measured value.
- Subtraction: Current – next measured value.
- Use
CLEARto remove last entry or reset line-by-line.
🔁 Advanced Features
4. Function Modes
Press the FUNC key to switch between these measurement types:
- Area Measurement:
S = Length × Width - Volume Measurement:
V = L × W × H - Pythagorean Measurement: Calculate height using indirect distances
- Double Pythagorean: Multi-step measurements for complex geometry
5. Data Storage & Recall
- Stores up to 30 sets of measurements automatically.
- Press
FUNCto access memory mode. - Use
+/-to browse saved values.
⚙️ Settings & Customization
6. Reference Point Setting
- Default reference is rear edge.
- Press the
↔key to toggle to front reference and back again.
7. Change Units
Hold the unit key to switch between:
- m (meters)
- ft (feet)
- in (inches)
- ft+in (feet-inch-1/16)
8. Clearing Entries
- Short press
CLEARto delete last action or line-by-line data.
🧪 Technical Specifications
| Feature | C6 Series | R7 Series |
|---|---|---|
| Range | 50m – 120m | 50m – 120m |
| Accuracy | ±2mm | ±2mm |
| Laser | Red Beam, Class 2, <1mW | Same |
| Functions | Area, Volume, Pythagorean | Same |
| Memory | 30 sets | 30 sets |
| Display Accuracy | 1mm | 1mm |
| Operation Temp | 0°C to 40°C | 0°C to 40°C |
| Storage Temp | -10°C to 50°C | -10°C to 50°C |
| Auto Laser Off | 30 seconds | 30 seconds |
| Auto Shutdown | 3 minutes | 3 minutes |
❗ Troubleshooting: Error Codes
| Error Code | Cause | Solution |
|---|---|---|
| Er104 | Calculation error | Re-measure |
| Er155 | Out of range | Move within range |
| Er157 | Weak signal or too slow | Use reflective targets |
| Er159 | Too much ambient light | Try low-reflectivity surfaces |
| Er194 | Numerical value too large | Stay within display limits |
🧠 Pro Tips
- Use a tripod for better long-distance accuracy.
- Clean the lens regularly.
- Avoid direct sunlight or overly reflective surfaces during measurements.